device: change logging interface to use functions
This commit overhauls wireguard-go's logging. The primary, motivating change is to use a function instead of a *log.Logger as the basic unit of logging. Using functions provides a lot more flexibility for people to bring their own logging system. It also introduces logging helper methods on Device. These reduce line noise at the call site. They also allow for log functions to be nil; when nil, instead of generating a log line and throwing it away, we don't bother generating it at all. This spares allocation and pointless work. This is a breaking change, although the fix required of clients is fairly straightforward. Signed-off-by: Josh Bleecher Snyder <josh@tailscale.com>
This commit is contained in:
committed by
Jason A. Donenfeld
parent
37efdcaccf
commit
7139279cd0
@@ -15,41 +15,37 @@ const DefaultMTU = 1420
|
||||
|
||||
func (device *Device) RoutineTUNEventReader() {
|
||||
setUp := false
|
||||
logDebug := device.log.Debug
|
||||
logInfo := device.log.Info
|
||||
logError := device.log.Error
|
||||
|
||||
logDebug.Println("Routine: event worker - started")
|
||||
device.debugf("Routine: event worker - started")
|
||||
|
||||
for event := range device.tun.device.Events() {
|
||||
if event&tun.EventMTUUpdate != 0 {
|
||||
mtu, err := device.tun.device.MTU()
|
||||
old := atomic.LoadInt32(&device.tun.mtu)
|
||||
if err != nil {
|
||||
logError.Println("Failed to load updated MTU of device:", err)
|
||||
device.errorf("Failed to load updated MTU of device: %v", err)
|
||||
} else if int(old) != mtu {
|
||||
if mtu+MessageTransportSize > MaxMessageSize {
|
||||
logInfo.Println("MTU updated:", mtu, "(too large)")
|
||||
device.infof("MTU updated: %v (too large)", mtu)
|
||||
} else {
|
||||
logInfo.Println("MTU updated:", mtu)
|
||||
device.infof("MTU updated: %v", mtu)
|
||||
}
|
||||
atomic.StoreInt32(&device.tun.mtu, int32(mtu))
|
||||
}
|
||||
}
|
||||
|
||||
if event&tun.EventUp != 0 && !setUp {
|
||||
logInfo.Println("Interface set up")
|
||||
device.infof("Interface set up")
|
||||
setUp = true
|
||||
device.Up()
|
||||
}
|
||||
|
||||
if event&tun.EventDown != 0 && setUp {
|
||||
logInfo.Println("Interface set down")
|
||||
device.infof("Interface set down")
|
||||
setUp = false
|
||||
device.Down()
|
||||
}
|
||||
}
|
||||
|
||||
logDebug.Println("Routine: event worker - stopped")
|
||||
device.debugf("Routine: event worker - stopped")
|
||||
device.state.stopping.Done()
|
||||
}
|
||||
|
||||
Reference in New Issue
Block a user